Electrical Application Details for App #: B288934
Premises: 15 LENOX ROAD BROOKLYN BIN: 3116220     Block: 5064   Lot: 110
  Printable (PDF) version of this Permit  

Filed: 15 LENOX RD Census Tract:   796 Health Area:  5320
BASEMENT SERVICE ONLY Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11226 Community Board:   314
DOB Cross Street(s):   FLATBUSH AVENUE,    BEDFORD AVENUE
Status:   I - AWAITING INSPECTION REQUEST
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/16/2007 9:07 AM
Application Entered:   03/16/2007 Job Start Date:   03/20/2007
Last Change:   03/16/2007 Job End Date:   11/20/2007
Appointment Status:   
Last Inspection By:          On          
Field Disp:   
Energize Recommendation:  
Objection Disposition:  

License #: 010377 Licensee Name: MICHAEL BAPTISTE
Firm: 002413 Firm Name: WCK ELECTRIC CORP.
Firm Phone: 917-909-1048  Firm Address: 1274 PROSPECT AVENUE BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $340.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: NORMAN CHARLES
Owner Business Name: NORMAN CHARLES
Authorized Representative:  NORMAN CHARLES
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  1X 400AMPS
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  4  4X250MCM
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  1X16 CKTPANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                        13 
Total Units : 13 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 13 #4-Wire 0 #10-Wire 0
Existing Meters 13 + New Meters 0 - Removed Meters 0 = Total Meters 13

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/16/2007 Notice:  
Power Issued: 03/16/2007 Response:  

Follow-Up:
Contractor's Comments:  UPGRADE ELECTRIC SERVICE TO 400 AMPS NO LOAD INCREASE NO RISERS

 
 

*NO INSPECTION RECORDS FOUND FOR ELECTRICAL APPLICATION NUMBER B288934
INSPECTION FOR APPLICATION #: B288934
INSP
ID
FIELD