NYC Department of Buildings
Electrical Application Details for App #: B284902
Premises: 222 PENN STREET BROOKLYN BIN: 3060847     Block: 2219   Lot: 35
   
Application Completed and Certified

Filed: 222 PENN ST Census Tract:   533 Health Area:  0500
CELLER Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11211 Community Board:   301
DOB Cross Street(s):   LEE AVENUE,    MARCY AVENUE
Status:   C - JOB IS SIGNED OFF 02/07/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/02/2006 2:39 PM
Application Entered:   11/02/2006 Job Start Date:   11/09/2006
Last Change:   02/07/2011 Job End Date:   11/09/2006
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     01/30/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010419 Licensee Name: LEZER S CHAIM
Firm: 000062 Firm Name: ACTION LIGHT & POWER, INC
Firm Phone: 718-422-1464  Firm Address: 383 WILLOUGHBY AVENUE BROOKLYN NY 11205 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ISSAC SPIRA
Owner Business Name: SAFE REALTY
Authorized Representative:  ISAAC SPIRA
Relationship To Owner:   MEMBER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/02/2006 Notice:  
Power Issued: 11/02/2006 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RENERGIZE 1 3-WIRE METER

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B284902
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/30/2011 02/07/2011 KAS C E (30) (0) Y
INSPECTION COMMENTS: N