Electrical Application Details for App #: B282561
Premises: 70 ROGERS AVENUE BROOKLYN BIN: 3324516     Block: 1232   Lot: 16
   
Application Completed and Certified

Filed: 70 ROGERS AV Census Tract:   221 Health Area:  2900
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11216 Community Board:   308
Related Job Number:    301929661
DOB Cross Street(s):   PROSPECT PLACE,    PARK PLACE
Status:   C - JOB IS SIGNED OFF 12/04/2007
Request Type:   Z - REFERRAL eFiled:   YES
Application Entered:   02/06/2007 Job Start Date:   02/09/2007
Last Change:   12/04/2007 Job End Date:   02/23/2007
Appointment Status:   
Last Inspection By:   MOSES, FITZROY       On     03/06/2007      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010918 Licensee Name: IGNACIO FOSTER
Firm: 002204 Firm Name: FINE ELECTRIC CO., INC.
Firm Phone: 718-360-1743  Firm Address: 604 JEROME STREET BROOKLYN NY 11204 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: WALDABA STEWARD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 6 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  01/23/2007
Power Issued: Response: F - FILED TO REMOVE OBJECTION 02/06/2007

Follow-Up: X - FILED APPL,NOW CLOSED 02/06/2007
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B282561
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/13/2006 09/18/2006 EBA N (30) (0)
INSPECTION COMMENTS: N
 
(2) 09/13/2006 09/18/2006 EBA N (30) (0)
INSPECTION COMMENTS: N
 
(3) 12/04/2006 12/12/2006 FMO N (15) (0) Y
INSPECTION COMMENTS: N
 
(4) 01/18/2007 01/23/2007 PGR W (30) (1) Y
INSPECTION COMMENTS: N
 
(5) 03/06/2007 03/12/2007 FMO C R E (45) (0) Y
INSPECTION COMMENTS: N