BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B269721
Premises: 151 CONOVER STREET BROOKLYN BIN: 3008580     Block: 565   Lot: 1
   

Filed: 118 WOLCOTT ST Census Tract:   57 Health Area:  4100
NONE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
Related Job Number:    301641043
DOB Cross Street(s):   VAN BRUNT STREET,    CONOVER STREET
Status:   K - CLOSED/CANCELLED 11/05/2007
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   07/19/2005 Job Start Date:   07/15/2005
Last Change:   11/05/2007 Job End Date:   08/08/2006
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     10/27/2007      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 011733 Licensee Name: ENSMAN ALEXANDER
Firm: 003321 Firm Name: ALKEM ELECTRICAL CORP
Firm Phone: 718-940-2957  Firm Address: 640 PARKSIDE AVENUE, STE 501 BROOKLYN NY 11226 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $145.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ALFRED THOMPSON
Owner Business Name: WOLCOTT PLACE LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 74  29  35              
Total Units : 154 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice: 1 - FIRST NOTICE 08/16/2005
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B269721
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/10/2005 08/16/2005 FMO A G (45) (8) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/09/2005 09/28/2005 CCH Z (0) (0) Y
INSPECTION COMMENTS: N
 
(3) 10/21/2005 10/31/2005 FMO Z (0) (0) Y
INSPECTION COMMENTS: N
 
(4) 10/27/2007 11/05/2007 KAS K (20) (0) Y
INSPECTION COMMENTS: SEE #B259105




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order