Electrical Application Details for App #: B240004
Premises: 623 STERLING PLACE BROOKLYN BIN: 3029294     Block: 1168   Lot: 77
   
Application Completed and Certified

Filed: 623 STERLING PL Census Tract:   217 Health Area:  2720
NONE Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11238 Community Board:   308
DOB Cross Street(s):   CLASSON AVENUE,    FRANKLIN AVENUE SHUTTLE LINE
Status:   C - JOB IS SIGNED OFF 04/01/2014
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/30/2003 Job Start Date:   06/10/2003
Last Change:   04/01/2014 Job End Date:   10/25/2004
Appointment Status:   
Last Inspection By:   BANYA, E       On     03/15/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010198 Licensee Name: JAMES KUNCZE
Firm: 002442 Firm Name: STERLING ELECTRIC INC.
Firm Phone: 718-953-8162  Firm Address: 8802 GLENWOOD ROAD BROOKLYN NY 11236 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $271.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: BEATRICE MINGO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  6  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 56  90  24  48  56                
Total Units : 274 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 6 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 05/30/2003 Notice: 1 - FIRST NOTICE 03/12/2012
Power Issued: 05/30/2003 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B240004
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/10/2004 09/24/2004 EFF Z (0) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 03/01/2012 03/12/2012 HRB V E (70) (5) Y
INSPECTION COMMENTS: N
 
(3) 03/15/2014 03/24/2014 EBA C R E (20) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B240004
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
NO BOND TO BUILDING STEEL
RSLV 03/01/2012 03/01/2012 03/15/2014
 
002 ( 5) SERVICE GROUNDING CONDUCTOR HAS NOT BEEN INSTALLED PROPERLY
NEED GROUND ROD
RSLV 03/01/2012 03/01/2012 03/15/2014
 
003 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
IN PLP PANEL AND KITCHEN
RSLV 03/01/2012 03/01/2012 03/15/2014
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
IN BASEMENT BELOW PLP PANEL AND KITCHEN
RSLV 03/01/2012 03/01/2012 03/15/2014
 
005 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
FOR OUTLETS IN BEDROOMS
RSLV 03/01/2012 03/01/2012 03/15/2014