Electrical Application Details for App #: B230747
Premises: 1104 PARK PLACE BROOKLYN BIN: 3031697     Block: 1244   Lot: 16
   
Application Completed and Certified

Filed: 1104 PARK PL Census Tract:   343 Health Area:  4900
218379 ENTIRE Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11213 Community Board:   308
DOB Cross Street(s):   KINGSTON AVENUE,    HAMPTON PLACE
Status:   C - JOB IS SIGNED OFF 03/17/2014 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/18/2002 Job Start Date:   09/05/2002
Last Change:   03/17/2014 Job End Date:   03/05/2003
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     12/19/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009252 Licensee Name: MORRIS HELLER
Firm: 000647 Firm Name: HELLER ELECTRIC CO., INC.
Firm Phone: 718-871-0800  Firm Address: 620 CONEY ISLAND AVE BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $298.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: MFA CONSTRUCTION INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 31  81  30              
Total Units : 157 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/18/2002 Notice: 1 - FIRST NOTICE 06/24/2013
Power Issued: 09/18/2002 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B230747
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/24/2012 10/01/2012 CJH N (30) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW
 
(2) 11/15/2012 11/16/2012 CCH N (15) (0) Y
INSPECTION COMMENTS: NO ACCESS
 
(3) 06/18/2013 06/24/2013 DEX A E (80) (9) Y
INSPECTION COMMENTS: N
 
(4) 07/23/2013 07/29/2013 CJH N (30) (0) Y
INSPECTION COMMENTS: N
 
(5) 12/19/2013 12/23/2013 PAT C R E (25) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B230747
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
1ST FL - DEFECTIVE GFCI OUTLET KITCHEN AREA
RSLV 06/18/2013 06/18/2013 12/19/2013
 
002 ( 18) DEFECTIVE RECEPTACLES ARE IN USE
3RD FL - DEFECTIVE GFCI OUTLET IN BATHROOM NO GROUND
RSLV 06/18/2013 06/18/2013 12/19/2013
 
003 (290) BATHROOM BRANCH CIRCUIT NOT PROVIDED
THROUGHOUT - ALL BATHROOMS NEED DEPENDENT CIRCUITS FOR GFCI OUTLETS
RSLV 06/18/2013 06/18/2013 12/19/2013
 
004 ( 35) APPROVED OUTLETS HAVE NOT BEEN PROVIDED FOR AIR CONDITIONERS
3RD FL- BEDROOM A/C NEEDS DEPENDENT CIRCUITS FOR GFCI OUTLETS
RSLV 06/18/2013 06/18/2013 12/19/2013
 
005 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
OUTSIDE - LIGHTS OUTSIDE NO GROUNDS FOR LIGHTS
RSLV 06/18/2013 06/18/2013 12/19/2013
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
OUTSIDE LIGHTS OUTSIDE NO GROUNDS
RSLV 06/18/2013 06/18/2013 12/19/2013
 
007 (101) CONDUCTORS AND/OR EQUIPMENT USED IS NOT APPROVED
OUTSIDE ROMEX USED OUTSIDE FEEDING LIGHTS NOT APPROVED FOR THEPURPOSE INTENDED
RSLV 06/18/2013 06/18/2013 12/19/2013
 
008 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
THROUGHOUT PUBLIC HALLWAY SENSORS FOR LIGHTS NOT GROUNDED
RSLV 06/18/2013 06/18/2013 12/19/2013
 
009 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
THROUGHOUT MC CABLES IN PANELS IN APARTMENT NOT BONDED TO PANELENCLOSURE
RSLV 06/18/2013 06/18/2013 12/19/2013