Electrical Application Details for App #: B189785
Premises: 471 CLARKSON AVENUE BROOKLYN BIN: 3327712     Block: 4829   Lot: 1
   
Application Completed and Certified

Filed: 471 CLARKSON AV Census Tract:   812 Health Area:  4800
001395 NONE Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11203 Community Board:   309
DOB Cross Street(s):   NEW YORK AVENUE,    EAST 37 STREET
Status:   C - JOB IS SIGNED OFF 11/20/2002
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/26/1999 Job Start Date:   05/25/1999
Last Change:   11/13/2002 Job End Date:   07/10/2002
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     10/24/2002      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011304 Licensee Name: ANGELO G RIGAS
Firm: 002708 Firm Name: ARC ELEC'L & MECH CONTRS
Firm Phone: 718-222-8162  Firm Address: 26 DELAVAN STREET CORP BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $18,510.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval # / Submittal #:   41555
Owner / Occup: THOMAS TILLELI
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  5  
C. 201 Up to 600 AMPS  10  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  1  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  16  
D. Over 250 MCM  22  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  5  
B. Over #2 to 1/0  10  
C. Over 1/0 to 250 MCM  10  
D. Over 250 MCM  5  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  94  
D. 3 Phase Over 225 AMPS  74  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 4500  3000    900  4500     800          500 
Total Units : 14200 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 11/06/2002 Notice:  11/27/2001
Power Issued: 05/26/1999 Response: W - OBJ TO BE REMOVED 12/06/2001

Follow-Up: K - (CLOSED)
Wires Comments: COMPL DATE CHANGE AS PER FC1, ORIG DATE WAS 7/10/99
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B189785
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/25/2000 10/11/2000 KAS J G (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/10/2001 11/27/2001 KAS V B (90) (7) Y
INSPECTION COMMENTS: 1)OF NEUT LINK,A)CUT OUT NOT GRP HGHER,B)100AMP ON GENERATORS,C)BOND ED,D)EMERGERCY POWER/FIRE ALARM,E)PUMPING LINE WITHIN SW BOARD
 
(4) 08/01/2002 08/12/2002 KAS H Y (150) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 10/24/2002 11/13/2002 KAS C R E (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application