Electrical Application Details for App #: B186773
Premises: 4018 5 AVENUE BROOKLYN BIN: 3324369     Block: 714   Lot: 44
   
Application Completed and Certified

Filed: 4018 5 AV Census Tract:   82 Health Area:  6600
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   J
BROOKLYN, NY 11232 Community Board:   307
DOB Cross Street(s):    40 STREET,    41 STREET
Status:   C - JOB IS SIGNED OFF 10/29/2009
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   01/14/2009 Job Start Date:   01/14/2009
Last Change:   10/29/2009 Job End Date:   01/11/2010
Appointment Status:   
Last Inspection By:   O'HARE, R.J.       On     05/19/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011729 Licensee Name: WILFRED JEFFREY
Firm: 003318 Firm Name: J.K.ELECTRICAL CONTRACTOR
Firm Phone: 718-369-0539  Firm Address: 247 PROSPECT AVENUE BROOKLYN NY 11225 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $47.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JACK GUELA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    16  15                 
Buildings Total 16  15                    
Total Units : 39 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  03/26/1999
Power Issued: Response: F - FILED TO REMOVE OBJECTION 01/14/2009

Follow-Up: X - FILED APPL,NOW CLOSED 01/14/2009
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B186773
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/08/1999 02/17/1999 RA1 W (10) (5)
INSPECTION COMMENTS: *ENCLOSURE NOT BONDED*.BASEMENT*COVERED-MISSING*SEALED
 
(2) 05/19/2009 05/22/2009 RJO C R E (30) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B186773
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
SERVICE EQUIPMENT* ENCLOSURE NOT BONDED*.BASEMENT*COVERED-MISSING*SEALED
RSLV 02/08/1999 02/08/1999 05/19/2009
 
002 ( 19) DEFECTIVE WIRING IS IN USE
DEFECTIVE WIRING IN
RSLV 02/08/1999 02/08/1999 05/19/2009
 
003 ( 29) OUTLET BOXES ARE NOT COVERED
OUTLET BOXES NOT
RSLV 02/08/1999 02/08/1999 05/19/2009
 
004 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PANELS KO'S NOT
RSLV 02/08/1999 02/08/1999 05/19/2009
 
005 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PANEL COVERS MISSING
RSLV 02/08/1999 02/08/1999 05/19/2009