BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B176826
Premises: 260 CORBIN PLACE BROOKLYN BIN: 3245741     Block: 8723   Lot: 269
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 270 CORBIN PL Census Tract:   610.02 Health Area:  9120
NONE Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   315
DOB Cross Street(s):   ORIENTAL BOULEVARD,    DEAD END
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/21/1998 Job Start Date:   04/22/1998
Last Change:   08/22/2025 Job End Date:   06/22/1998
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   ROBERT SPRUNG       On     01/06/1999      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 011334 Licensee Name: MICHAEL KATZ
Firm: 002750 Firm Name: A & M ELEC'L SERVICE INC.
Firm Phone: 718-668-1908  Firm Address: 516 INDUSTRIAL LOOP S.I NY 10309 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $319.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: VADIM KHRAKOVSKY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 50  100    30  50     61           
Total Units : 291 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/21/1998 Notice:  
Power Issued: 04/21/1998 Response:  

Follow-Up:
Wires Comments: WE WORK TO INCREASE SERVICE TO 30.NEED 30 METER INSTEAD OF SINGLE
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B176826
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/23/1998 06/29/1998 BK1 J G (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/05/1998 08/12/1998 BK1 J G (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/04/1998 09/09/1998 BK1 J (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/16/1998 12/21/1998 RSP J (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 01/06/1999 01/11/1999 RSP J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 07/23/1999 08/03/1999 RA1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 01/19/2001 02/13/2001 EFF Z (1) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application