Electrical Application Details for App #: B165192
Premises: 20 BRIGHTON 1 WALK BROOKLYN BIN: 3256959     Block: 8671   Lot: 52
   
Application Completed and Certified

Filed: 225 BRIGHTON 1 WALK Census Tract:   362 Health Area:  9110
WHOLE HOUSE Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   313
DOB Cross Street(s):   BRIGHTON 1 PLACE,    BRIGHTON 1 PATH
Status:   C - JOB IS SIGNED OFF 07/15/1999
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/28/1997 Job Start Date:   04/30/1997
Last Change:   04/09/1999 Job End Date:   05/30/1997
Appointment Status:   
Last Inspection By:   ROBERT SPRUNG       On     04/06/1999      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010759 Licensee Name: YOUNG S CHOE
Firm: 001995 Firm Name: Y.S ELECTRIC
Firm Phone: 866-863-4448  Firm Address: 129-09 26TH AVENUE, #103 FLUSHING NY 11354 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $162.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: YUN JEUNG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10  20    15  10                
Total Units : 55 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 02/08/1999 Notice: C - CALL TO OFFICE 01/07/1999
Power Issued: 04/28/1997 Response: R - REINSPECTION 06/11/1998

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B165192
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/01/1997 10/10/1997 BK1 P (75) (0)
INSPECTION COMMENTS: ALSO 3 TEMP NEW BLDG
 
(2) 03/20/1998 03/31/1998 BK1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/11/1998 05/19/1998 BK1 V B (65) (11)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 07/16/1998 07/21/1998 BK1 V R B (60) (8)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 12/28/1998 01/07/1999 RSP H X B (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 02/01/1999 02/08/1999 RSP H Y B (90) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 04/06/1999 04/09/1999 RSP C R E (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application