Electrical Application Details for App #: B159871
Premises: 205 PROSPECT PARK WEST BROOKLYN BIN: 3330765     Block: 1106   Lot: 3
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 205 PROSPECT PARK W Census Tract:   169 Health Area:  4700
10724 N/A Admin Area:   B - BROOKLYN Inspection Area:   F
BROOKLYN, NY 11215 Community Board:   307
DOB Cross Street(s):   PROSPECT PARK SOUTHWEST,    16 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/20/1996 Job Start Date:   11/07/1996
Last Change:   08/22/2025 Job End Date:   11/10/1997
Appointment Status:   
Last Inspection By:   ALTON ROSE       On     12/04/1998      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010551 Licensee Name: BRUCE BECKWITH
Firm: 001746 Firm Name: M.B.S. ELECTRIC INC.
Firm Phone: 718-358-3400  Firm Address: 65-50 FRESH MEADOW LANE FLUSHING NY 11365 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   NYNEX EQUIPMENT
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: NYNEX
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   M-F 8-4PM Contact Phone:   718 358 3400

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/20/1996 Notice:  
Power Issued: 11/20/1996 Response:  

Follow-Up:
Contractor's Comments:  NYNEX V.G VAULT. SIDE OF ADDRESS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B159871
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/25/1997 08/18/1997 LEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/22/1997 09/06/1997 LEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/19/1997 10/14/1997 LEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 11/06/1997 11/19/1997 LEN N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 04/02/1998 04/14/1998 LEN N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/14/1998 05/20/1998 LEN N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/26/1998 07/10/1998 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 12/04/1998 12/14/1998 RA1 N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 03/03/2000 03/17/2000 KAS Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 09/14/2001 09/20/2001 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application