Electrical Application Details for App #: B154584
Premises: 746 UTICA AVENUE BROOKLYN BIN: 3327582     Block: 4655   Lot: 3
   

Filed: 744 UTICA AV Census Tract:   868 Health Area:  5510
SIGN Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11203 Community Board:   317
DOB Cross Street(s):   LENOX ROAD,    LINDEN BOULEVARD
Status:   C - COMPLETED
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/25/1996 Job Start Date:   06/21/1996
Last Change:   08/13/1996 Job End Date:   06/21/1996
Appointment Status:   
Last Inspection By:   COEN, MICHAEL       On     08/06/1996      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010804 Licensee Name: SANG CHEUNG
Firm: 002065 Firm Name: AL-LECTRIC ELECT'L CONTRG
Firm Phone: 212-219-3336  Firm Address: 137 CHRYSTIE STREET NEW YORK NY 10002 

Work Started or Filed by Others: NO
Work Category:   S - SHOP INSPECTION Work To Be Done:   Total Fee:  $0.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   IMPORT
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: CARDEL ENTERPRISES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Sign Dimensions : 2 Ft 0 In  BY  4 Ft 0 In  Total Sq. Ft. of Sign: 8
Sign Type :
Total Circuits: 1 Total Lamps: 2
Watts (Lamps): 200 Number of Trans: 1 VA of Each Trans: 0
Total Watts or VA: 0 A.W. Gauge of Wire: 14 No. of Sockets Per Circuit: 0
Material/Gauge:
Sign Maker : ALLIED SIGN CORP
Sign Maker Address: 1190 UTICA AVENE
Shop Address:
Shop Phone:
Shop Location Comments:
Sign Text: BROOKLYN NY 11203

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  300537774

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B154584
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/06/1996 08/13/1996 MC1 C (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order