Electrical Application Details for App #: B150221
Premises: 788 PARK PLACE BROOKLYN BIN: 3031496     Block: 1240   Lot: 21
   
Application Completed and Certified

Filed: 788 PARK PL Census Tract:   317.01 Health Area:  2900
NONE Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11216 Community Board:   308
DOB Cross Street(s):   ROGERS AVENUE,    NOSTRAND AVENUE
Status:   C - JOB IS SIGNED OFF 07/11/2006
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/20/1996 Job Start Date:   02/09/1996
Last Change:   07/11/2006 Job End Date:   02/19/1996
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     07/05/2006      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010227 Licensee Name: REGINALD M LOWE
Firm: 001026 Firm Name: MORRAY ELECTRIC CORP.
Firm Phone: 718-495-2821  Firm Address: 276 JUNIUS STREET BROOKLYN NY 11212 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $160.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: CHRISTINE PORTER-TZORTZIS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9 TO 5PM Contact Phone:   718 622-2824

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 16 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/20/1996 Notice:  
Power Issued: 02/20/1996 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: INSTALL SERVICE FOR 16 METERS
Contractor's Comments:  BASEMENT ONLY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B150221
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/11/1997 04/15/1997 MC1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/19/1997 12/17/1997 X01 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/26/1998 05/18/1998 X01 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 07/05/2006 07/10/2006 DEX C E (15) (0)
INSPECTION COMMENTS: N