BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B121898
Premises: 1180 BRIGHTON BEACH AVENUE BROOKLYN BIN: 3394169     Block: 8723   Lot: 400
   
Application Completed and Certified

Filed: 1182 BRIGHTON BEACH AV Census Tract:   610.02 Health Area:  9120
NONE Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   313
DOB Cross Street(s):   BRIGHTON 15 STREET,    CORBIN PLACE
Status:   C - JOB IS SIGNED OFF 01/18/2002
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/24/1994 Job Start Date:   01/14/1994
Last Change:   12/31/2001 Job End Date:   01/21/1994
Appointment Status:   
Last Inspection By:   ALTON ROSE       On     12/20/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 009802 Licensee Name: PETER J CATANZARO
Firm: 001146 Firm Name: PETER J. CATANZARO, INC.
Firm Phone: 718-832-3230  Firm Address: 126 41ST STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $95.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   SYNAGOGUE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: TEMPLE BETH AVE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 55  26  15  49                
Total Units : 152 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 01/24/1994 Notice: 1 - FIRST NOTICE 01/14/2000
Power Issued: 01/24/1994 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B121898
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/16/1994 01/06/1995 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/17/1995 01/27/1995 LF1 N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 08/11/1997 08/15/1997 BK1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/18/1997 12/26/1997 BK1 N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 02/06/1998 02/21/1998 BK1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/20/1998 05/28/1998 BK1 N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/12/1998 06/27/1998 BK1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 07/02/1999 07/12/1999 RA1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 01/11/2000 01/14/2000 RA1 V G (90) (7) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 06/27/2000 07/07/2000 RA1 N (15) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 11/26/2001 11/30/2001 RA1 N (30) (0) Y
INSPECTION COMMENTS: LEFT CARD
 
(12) 12/20/2001 12/31/2001 RA1 C R (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order