Electrical Application Details for App #: B113482
Premises: 4 WATER STREET BROOKLYN BIN: 3391190     Block: 35   Lot: 16
   
Application Completed and Certified

Filed: 4 WATER ST Census Tract:   21 Health Area:  1000
NONE Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   OLD FULTON STREET,    BROOKLYN BRIDGE
Status:   C - JOB IS SIGNED OFF 06/13/2012 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/21/1993 Job Start Date:   06/15/1993
Last Change:   06/13/2012 Job End Date:   07/15/1993
Appointment Status:   
Last Inspection By:   MOSES, FITZROY       On     02/28/2007      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009366 Licensee Name: ODESSEFS PARASCO
Firm: 000133 Firm Name: AMTEX ELEC'L CORP.
Firm Phone: 718-274-5505  Firm Address: 26-20 HOYT AVE. SOUTH LIC NY 11102 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
Total Fee:  $192.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: WATER FRONT REALTY CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 120        120                
Total Units : 240 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/21/1993 Notice:  
Power Issued: 06/21/1993 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: TEMPY LIGTS POWR FOR RENOVTN
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B113482
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/05/1993 11/24/1993 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 12/03/1993 12/27/1993 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 12/31/1993 01/20/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 02/25/1994 03/17/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 12/01/1995 01/10/1996 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 01/12/1996 02/01/1996 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 02/09/1996 02/27/1996 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 01/10/1997 02/12/1997 MC1 J G (34) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 11/07/1997 11/13/1997 MC1 J G (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 03/06/1998 04/18/1998 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 02/28/2007 03/05/2007 FMO C E (15) (0) Y
INSPECTION COMMENTS: N