BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B107484
Premises: 232 SACKETT STREET BROOKLYN BIN: 3004323     Block: 338   Lot: 17
   
Application Completed and Certified

Filed: 232 SACKETT ST Census Tract:   67 Health Area:  4000
CELLER Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11231 Community Board:   306
DOB Cross Street(s):   HENRY STREET,    CLINTON STREET
Status:   C - JOB IS SIGNED OFF 04/20/1993
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   12/29/1992 Job Start Date:   02/11/1993
Last Change:   04/02/1993 Job End Date:   03/11/1993
Appointment Status:   
Last Inspection By:   COEN, MICHAEL       On     03/25/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010893 Licensee Name: ARNOLD KHALEVICH
Firm: 002177 Firm Name: ADL ELECTRIC INC.
Firm Phone: 718-851-9353  Firm Address: 3925 NEW UTRECHT AVENUE BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $526.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: A FARRAJ
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  11  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9AM TO 5PM Contact Phone:   781 643-0241

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 03/08/1993 Notice:  03/08/1993
Power Issued: 03/08/1993 Response: F - FILED TO REMOVE OBJECTION 03/08/1993

Follow-Up: X - FILED APPL,NOW CLOSED 03/08/1993
Contractor's Comments:  CLEMSON HENRY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B107484
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/10/1992 12/29/1992 MC1 W (19) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 03/25/1993 04/02/1993 MC1 C R E (85) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order