Premises: 206 OCEAN VIEW AVENUE BROOKLYN BIN: 3244641     Block: 8671   Lot: 20
   
Application Completed and Certified

Filed: 206 OCEANVIEW AV Census Tract:   362 Health Area:  9110
BSMT 1 FL Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   313
DOB Cross Street(s):   BRIGHTON 1 STREET,    BRIGHTON 2 STREET
Status:   C - JOB IS SIGNED OFF 10/10/1996
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/26/1992 Job Start Date:   02/26/1992
Last Change:   08/15/1996 Job End Date:   03/03/1992
Appointment Status:   
Last Inspection By:   KAGAN, B.       On     08/13/1996      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009365 Licensee Name: MICHAEL SCHONDORF
Firm: 000995 Firm Name: MICHAEL SCHONDORF, INC
Firm Phone: 212-244-4312  Firm Address: 545 WEST 45TH STREET..6F NEW YORK NY 10036 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $95.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: OLGA OSTEROVKO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 02/05/1996 Notice:  02/05/1996
Power Issued: 03/04/1992 Response: R - REINSPECTION 02/15/1996

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B095804
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/17/1992 08/05/1992 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/17/1992 08/25/1992 JMC N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/19/1995 06/09/1995 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 11/24/1995 11/27/1995 BK1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 01/10/1996 02/05/1996 BK1 V B (65) (5)
INSPECTION COMMENTS: MAIN BR IS NOT PROVIDED. TWO BREAKERS ARE NOT BOLTED IN. NOT AT NEAR EST PAINT 17-18 3045. RUN IN HOLLOWS OF BLDG-3044A3
 
(6) 07/23/1996 07/30/1996 BK1 S (0) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 08/13/1996 08/15/1996 BK1 C R E (55) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application