Premises: 508 FULTON STREET BROOKLYN BIN: 3000458     Block: 160   Lot: 18
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 510 FULTON ST Census Tract:   37 Health Area:  2400
BASEMENT 11FL Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   BOND STREET,    HANOVER PLACE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/21/1990 Job Start Date:   11/20/1990
Last Change:   08/22/2025 Job End Date:   12/28/1990
Appointment Status:   
Last Inspection By:   COLON, WILFREDO JR       On     05/21/1992      
Field Disp:   L - LOCATION PROBLEM
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010661 Licensee Name: DOMINICK R FERELLO
Firm: 002563 Firm Name: K & D ELECTRIC, INC.
Firm Phone: 718-343-0433  Firm Address: 32 EAST 31 STREET 8 FL SUITE-A NEW YORK NY 10016 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $820.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   RETAIL STORES
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: WORTHEIMER DEPT STORE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  8  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  7  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total              10           
Total Units : 10 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9AM TO 5PM Contact Phone:   718/527-8900

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 3 #10-Wire 5
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 11/21/1990 Notice:  
Power Issued: 11/21/1990 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B076921
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/06/1991 12/23/1991 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/03/1992 01/24/1992 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 02/11/1992 04/17/1992 MC1 C E (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 05/21/1992 05/29/1992 WC1 L (5) (0)
INSPECTION COMMENTS: WHAT WORK