BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B066361
Premises: 112 MANHATTAN AVENUE BROOKLYN BIN: 3071277     Block: 3070   Lot: 7
   
Application Completed and Certified

Filed: 112 MANHATTAN AV Census Tract:   505 Health Area:  1500
1FL 2FL 1-4 Admin Area:   B - BROOKLYN Inspection Area:   B
BROOKLYN, NY 11206 Community Board:   301
DOB Cross Street(s):   BOERUM STREET,    JOHNSON AVENUE
Status:   C - JOB IS SIGNED OFF 01/03/1995
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/16/1990 Job Start Date:   04/29/1990
Last Change:   11/16/1994 Job End Date:   05/02/1990
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     10/25/1994      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010089 Licensee Name: JOSEPH MYERS
Firm: 000045 Firm Name: A-ULTIMATE EL. CON.&MGMT.
Firm Phone: 646-552-9547  Firm Address: 2376 ADAM CLAYTON POWELL BL SI NEW YORK NY 10030 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $151.50
Other Work:   COMPLEAT REWIRING ON 4 APTS
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:   A - ADEQUATE WIRING PROGRAM
Advisory Board Approval:  
Owner / Occup: JOSE FERER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  5  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 16  32  12                  
Total Units : 64 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 04/16/1990 Notice:  
Power Issued: 04/16/1990 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: COMPLET WIRING OF A FAMILY HOUSE
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B066361
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/11/1990 06/01/1990 NEI Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 04/10/1992 04/30/1992 KAS Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/12/1992 05/19/1992 KAS N (20) (0)
INSPECTION COMMENTS: NONE
 
(4) 10/25/1994 11/16/1994 X01 C G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order