BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B062444
Premises: 1 FULTON STREET BROOKLYN BIN: 3000078     Block: 42   Lot: 18
   
Application Completed and Certified

Filed: 254 WATER ST Census Tract:   21 Health Area:  1000
EXTERIOR Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   BRIDGE STREET,    GOLD STREET
Status:   C - JOB IS SIGNED OFF 12/29/1995
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/23/1990 Job Start Date:   01/22/1990
Last Change:   12/29/1995 Job End Date:   01/31/1990
Appointment Status:   
Last Inspection By:   COEN, MICHAEL       On     12/20/1995      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010705 Licensee Name: WARREN JOHNSEN
Firm: 000779 Firm Name: JOHNSON BROTHERS INC
Firm Phone: 718-461-2600  Firm Address: 15-03 132ND STREET COLLEGE POINT NY 11356 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $10.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   BUILDING
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: D.G.S. - CITY OF N.Y
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 8 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: DGS- PROJECT NO. 856-3200-408 SECURITY LIGHTING - PARKING LOT
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B062444
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/22/1995 10/16/1995 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/20/1995 11/04/1995 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 11/17/1995 12/02/1995 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/20/1995 12/29/1995 MC1 C G (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back