BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B056408
Premises: 810 OCEAN AVENUE BROOKLYN BIN: 3118798     Block: 5162   Lot: 18
   
Application Completed and Certified

Filed: 810 OCEAN AV Census Tract:   514 Health Area:  7210
BSMT Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11226 Community Board:   314
DOB Cross Street(s):   CORTELYOU ROAD,    DORCHESTER ROAD
Status:   C - JOB IS SIGNED OFF 06/11/1993
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/16/1989 Job Start Date:   08/09/1989
Last Change:   05/13/1993 Job End Date:   08/15/1989
Appointment Status:   
Last Inspection By:   LEITNER, L.       On     05/03/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010133 Licensee Name: JOHN MUSTARO
Firm: 001167 Firm Name: POLYPHASE ELEC'L CONTR'S.
Firm Phone: 718-449-1003  Firm Address: 2201 NEPTUNE AVENUE BROOKLYN NY 11224 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $386.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 800 OCEAN AVENUE REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  15  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  15  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   MON-FRI 9-5 Contact Phone:   377 5439

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 15 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 03/28/1990 Notice: C - CALL TO OFFICE 03/28/1990
Power Issued: Response: R - REINSPECTION 12/07/1989

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B056408
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/06/1989 11/16/1989 SS1 V B (55) (2)
INSPECTION COMMENTS: NONE
 
(2) 03/22/1990 03/28/1990 SS1 H X B (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 04/25/1990 05/01/1990 SS1 J R E (75) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/17/1990 09/06/1990 MC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 02/14/1991 02/20/1991 RJO N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 09/25/1992 10/14/1992 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 10/23/1992 11/12/1992 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 11/23/1992 12/02/1992 LF1 N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 03/26/1993 04/13/1993 LEN Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 05/03/1993 05/13/1993 LEN C E (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order