BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B050320
Premises: 501 BRIGHTWATER COURT BROOKLYN BIN: 3245102     Block: 8689   Lot: 97
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 501 BRIGHTWATER COURT Census Tract:   360.02 Health Area:  9110
104 Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   313
DOB Cross Street(s):   BRIGHTON 5 STREET,    BRIGHTON 6 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/22/1989 Job Start Date:   02/22/1989
Last Change:   08/22/2025 Job End Date:   02/22/1989
Appointment Status:   
Last Inspection By:   JAMES CLANCY       On     08/25/2008      
Field Disp:   P - PARTIAL NO ACCESS
Energize Recommendation:  B - CANCEL POWER AUTH
Objection Disposition:  

License #: 009460 Licensee Name: R SHAPIRO
Firm: 001577 Firm Name: GALAXY ELECT. CONTR. CORP
Firm Phone: 718-742-3200  Firm Address: 2166 EAST 7TH STREET BROOKLYN NY 11223 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $31.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: VLADIMIR YVZHUK
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10  22                
Total Units : 44 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9AM TO 3PM Contact Phone:   718 743 3200

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 05/02/1989 Notice: 1 - FIRST NOTICE 05/02/1989
Power Issued: 03/22/1989 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B050320
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/21/1989 05/02/1989 NEI V B (50) (4)
INSPECTION COMMENTS: NO
 
(2) 05/20/1994 06/08/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 06/17/1994 07/08/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 07/15/1994 08/02/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 08/12/1994 09/01/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 09/09/1994 09/29/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 10/07/1994 10/18/1994 JMC Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 08/25/2008 09/03/2008 JMZ P (30) (0) Y
INSPECTION COMMENTS: N




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back