BIS Menu  |  Marquee Query  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B045010
Premises: 1792 NOSTRAND AVENUE BROOKLYN BIN: 3120038     Block: 5195   Lot: 26
   
Application Completed and Certified

Filed: 1792 NOSTRAND AV Census Tract:   828 Health Area:  7410
BSMT & STORE Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11226 Community Board:   317
DOB Cross Street(s):   CLARENDON ROAD,    AVENUE D
Status:   C - JOB IS SIGNED OFF 10/22/1996
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/02/1988 Job Start Date:   11/03/1988
Last Change:   09/05/1996 Job End Date:   11/04/1988
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     08/26/1996      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009198 Licensee Name: S FROMCHUCK
Firm: 000436 Firm Name: DONALD MCGEACHY, INC.
Firm Phone: 212-249-0999  Firm Address: 502A EAST 84 STREET NEW YORK NY 10028 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $42.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   GROCERY
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: JOSEPH H GILLES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   ANYTIME Contact Phone:   634-6432

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/02/1988 Notice:  
Power Issued: 11/02/1988 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B045010
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/06/1989 01/23/1989 JAN Z (1) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/13/1989 07/21/1989 MC1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/26/1991 04/04/1991 LF1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/26/1991 05/16/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 05/24/1991 06/12/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 07/19/1991 08/09/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 08/16/1991 09/11/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 09/13/1991 10/07/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 10/11/1991 10/31/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 11/08/1991 11/29/1991 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 12/12/1991 12/18/1991 LF1 N (25) (0)
INSPECTION COMMENTS: NO KEYS
 
(12) 04/06/1993 04/09/1993 LF1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(13) 06/05/1993 06/08/1993 LF1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(14) 07/25/1994 09/29/1994 X01 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(15) 06/30/1995 07/20/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(16) 07/28/1995 08/22/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(17) 08/25/1995 09/12/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(18) 09/22/1995 10/16/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(19) 10/20/1995 11/04/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(20) 11/17/1995 12/02/1995 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(21) 12/15/1995 01/10/1996 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(22) 01/12/1996 01/27/1996 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(23) 02/09/1996 02/27/1996 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(24) 08/26/1996 09/05/1996 KAS C (50) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application