BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B044229
Premises: 24 6 AVENUE BROOKLYN BIN: 3027597     Block: 1127   Lot: 7501
   

Filed: 24 SIXTH AV Census Tract:   129.02 Health Area:  2600
ELEVATROR SHAF Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11217 Community Board:   306
DOB Cross Street(s):   PACIFIC STREET,    DEAN STREET
Status:   K - CLOSED/CANCELLED 11/05/1999
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/18/1988 Job Start Date:   08/09/1988
Last Change:   06/02/1993 Job End Date:   08/10/1988
Appointment Status:   
Last Inspection By:   ADMINISTRATION       On     11/05/1999      
Field Disp:   P - PARTIAL NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 009828 Licensee Name: KENNETH R SEIFERTH
Firm: 001512 Firm Name: WARREN ELEVATOR SVC CO
Firm Phone: 718-389-1234  Firm Address: 227 EAGLE STREET BROOKLYN NY 11222 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $5.00
Other Work:   110V AC TRAVEL CABLE FROM PANEL BOX IN BSM
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   F - Factory
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: JORDAN MANUFACTURING CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 2 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   MON TO FRI 9 AM TO 4 PM Contact Phone:   718 622 0151

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  JORDAN MANUFACTURING CORP ELEVATOR SHAFT

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B044229
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/21/1993 05/26/1993 AG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/29/1993 06/02/1993 LF1 P (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back