NYC Department of Buildings
Electrical Application Details for App #: B022936
Premises: 1346 ST MARKS AVENUE BROOKLYN BIN: 3036117     Block: 1363   Lot: 25
   
Application Completed and Certified

Filed: 1346 ST MARKS AV Census Tract:   359 Health Area:  5020
7K10398 BLDG Admin Area:   B - BROOKLYN Inspection Area:   H
BROOKLYN, NY 11233 Community Board:   308
DOB Cross Street(s):   BUFFALO AVENUE,    RALPH AVENUE
Status:   C - JOB IS SIGNED OFF 12/12/1994
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/23/1987 Job Start Date:   06/18/1987
Last Change:   11/10/1994 Job End Date:   06/30/1987
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     10/11/1994      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 009606 Licensee Name: LEO GOODMAN
Firm: 002019 Firm Name: N.Y. METRO INDUSTRIES INC
Firm Phone: 718-805-5600  Firm Address: 122-36 FARMERS BLVD. JAMAICA NY 11413 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $23.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: HPD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 07/23/1987 Notice:  07/23/1987
Power Issued: 06/23/1987 Response: R - REINSPECTION 08/10/1987

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B022936
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/21/1987 07/23/1987 HVJ A B (35) (1)
INSPECTION COMMENTS: 5-CONNECTED TO GROUNDING ELECTRIC ON S.S
 
(2) 10/11/1994 11/10/1994 X01 C R G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application