BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B019382
Premises: 323 LINCOLN PLACE BROOKLYN BIN: 3029533     Block: 1176   Lot: 70
   

DOB NOW: Inspections


Filed: 323 LINCOLN PL Census Tract:   215 Health Area:  2720
NOT GIVEN Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11238 Community Board:   308
DOB Cross Street(s):   UNDERHILL AVENUE,    WASHINGTON AVENUE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 12/30/2015
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/21/1987 Job Start Date:   04/21/1987
Last Change:   12/30/2015 Job End Date:   04/29/1987
Appointment Status:   
Last Inspection By:   JEFFERSON, CHARLES       On     12/29/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009918 Licensee Name: F GROOS
Firm: 001441 Firm Name: TOP-LITE ELEC. SVC. CORP.
Firm Phone: 718-738-0200  Firm Address: 116-02 ROCKAWAY BLVD QUEENS NY 11420 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
8 - BOILER/BURNER WIRING
Total Fee:  $17.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: LINCOLN PLACE ASSOCIATES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/09/2015 Notice: 1 - FIRST NOTICE 11/09/2015
Power Issued: 11/09/2015 Response: R - REINSPECTION 07/14/1987

Follow-Up: K - (CLOSED)
Wires Comments: BASEMENT WIRING FOR OIL FIRED BOILER
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B019382
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/22/1987 07/07/1987 WMK A G (25) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/17/1987 08/21/1987 JB1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 11/04/2015 11/09/2015 CJH A R E (20) (3) Y
INSPECTION COMMENTS: N
 
(4) 12/29/2015 12/30/2015 CJE C R (5) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED.

OBJECTION FOR APPLICATION #: B019382
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 29) OUTLET BOXES ARE NOT COVERED
BST BOIL RM
RSLV 06/22/1987 06/22/1987 11/04/2015
 
002 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
BSTBELLWIRE USDED TO WIRE BOILR CONTROL NOT APPROV B30 71.OC B- BOIL DISC SW NOT INSTALL AT BOILR RM ENT NOT ON CEILNG B30-103.OF
RSLV 06/22/1987 06/22/1987 11/04/2015
 
003 (999) OTHER
(ALL FLOORS) CELLAR BOILER RM LUMINARIES BOILER SHARE CKT 422.12
RSLV 11/04/2015 11/04/2015 12/29/2015
 
004 (999) OTHER
(ALL FLOORS) CELLAR BOILER SWITCH NOT PROPERLY IDENTIFIED 110.2
RSLV 11/04/2015 11/04/2015 12/29/2015
 
005 (999) OTHER
(ALL FLOORS)CELLAR BOILER CONDUCTOR NOT PROTECTED FROM ABRAISION 110.2
RSLV 11/04/2015 11/04/2015 12/29/2015