BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B016218
Premises: 526 PENNSYLVANIA AVENUE BROOKLYN BIN: 3085056     Block: 3822   Lot: 31
   

Filed: 526 PENNSYLVANIA AV Census Tract:   1126 Health Area:  6300
ENTIRE BLDG Admin Area:   B - BROOKLYN Inspection Area:   H
BROOKLYN, NY 11207 Community Board:   305
DOB Cross Street(s):   LIVONIA AVENUE,    RIVERDALE AVENUE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 07/05/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/20/1987 Job Start Date:   06/20/1986
Last Change:   07/05/1988 Job End Date:   03/01/1987
Appointment Status:   
Last Inspection By:   NAJARIAN, E.       On     06/27/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  X - NOT REMOVED

License #: 010330 Licensee Name: A ADAMS
Firm: 000091 Firm Name: ALDWYN F. ADAMS
Firm Phone: 718-756-2319  Firm Address: 1904 CHURCH AVENUE BROOKLYN NY 11226 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $817.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ALDWYN ADAMP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  32  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  32  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 32 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 02/20/1987 Notice: C - CALL TO OFFICE 06/13/1988
Power Issued: 02/20/1987 Response: R - REINSPECTION 10/05/1987

Follow-Up: K - (CLOSED)
Wires Comments: RE-ENERGIZE EXISTING SERVICE SECOND TIME/DUE TO FIRE
Contractor's Comments:  ASS.TO EN1 FOR 880624 AS PER M/K ON PRINTOUT ON 880627

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B016218
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/01/1987 04/10/1987 HVJ V D (30) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/02/1987 09/10/1987 HVJ H X D (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/26/1987 10/30/1987 HVJ H X D (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/30/1987 01/12/1988 FW1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 05/16/1988 05/25/1988 EN1 N (15) (0)
INSPECTION COMMENTS: PRRV 100 LEFT 115
 
(6) 05/20/1988 06/13/1988 EN1 H X G (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/21/1988 06/27/1988 EN1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 06/27/1988 07/05/1988 EN1 C E (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order