Electrical Application Details for App #: B016123
Premises: 150 BRIGHTON 15 STREET BROOKLYN BIN: 3245671     Block: 8717   Lot: 29
   
Application Completed and Certified

Filed: 150 BRIGHTON 15 ST Census Tract:   610.01 Health Area:  9120
NONE Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   313
DOB Cross Street(s):   CORBIN PLACE,    BRIGHTON BEACH AVENUE
Status:   C - JOB IS SIGNED OFF 10/31/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/19/1987 Job Start Date:   02/18/1987
Last Change:   10/17/1988 Job End Date:   02/25/1987
Appointment Status:   
Last Inspection By:   ISAAC, N.       On     10/13/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009243 Licensee Name: WILLIAM C LOPRESTI
Firm: 000386 Firm Name: DARBY ENTERPRISES INC.
Firm Phone: 718-969-2700  Firm Address: 162-20 77TH ROAD FLUSHING NY 11366 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $27.75
Other Work:   X-RAY
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: DR.PETER J.PLOTNIK
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                        25 
Total Units : 25 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   ANYTIME -ALWAYS THERE Contact Phone:   718 891-2990

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: NEW METER AND PANEL IN BASEMENT TO ACCOMODATE X-RAY
Contractor's Comments:  SERVICE LOCATED-BASEMENT-FRONT OF ELEVATOR

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B016123
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/16/1987 03/26/1987 LR1 J G (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/09/1987 10/20/1987 JMC N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 04/29/1988 05/06/1988 FL1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 10/13/1988 10/17/1988 NEI C E (60) (0)
INSPECTION COMMENTS: SUPT ATP 2K