BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B008874
Premises: 1801 FLATBUSH AVENUE BROOKLYN BIN: 3403348     Block: 7618   Lot: 26
   
Application Completed and Certified

Filed: 1801 FLATBUSH AV Census Tract:   740 Health Area:  8810
FRONT OF STORE Admin Area:   B - BROOKLYN Inspection Area:   Q
BROOKLYN, NY 11210 Community Board:   318
DOB Cross Street(s):   EAST 36 STREET,    EAST 37 STREET
Status:   C - JOB IS SIGNED OFF 08/02/2011
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   07/19/2010 Job Start Date:   07/19/2010
Last Change:   08/02/2011 Job End Date:   08/19/2010
Appointment Status:   
Last Inspection By:   COHN, MARTIN       On     07/28/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010254 Licensee Name: PINCHUS BELSKY
Firm: 002540 Firm Name: CROWN ELEC'L CONTR'S INC.
Firm Phone: 718-438-6004  Firm Address: 4016 18 AVENUE BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $40.00
Other Work:   REMOVE WIRING
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   ELECTRONIC
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: COMPUTER HARMONY
Owner Business Name: H COMPUTER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
SWK                       
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/01/2011 Notice: C - CALL TO OFFICE 01/31/2011
Power Issued: 08/01/2011 Response: F - FILED TO REMOVE OBJECTION 07/19/2010

Follow-Up: X - FILED APPL,NOW CLOSED 07/19/2010
Contractor's Comments:  REMOVE ALL ELECTRICAL BOXES AND PIPING FROM SIGN

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B008874
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/14/1986 09/23/1986 JMC W (20) (3)
INSPECTION COMMENTS: 56 INSTALLATIONA ND CONNECTION OF SIGN B30 211.0 3 BR CIR CONNECTION OF SIGN
 
(2) 09/21/2010 09/24/2010 MC2 H X (15) (0) Y
INSPECTION COMMENTS: P/U 3W THROUGHOUT ROMEX
 
(3) 01/26/2011 01/31/2011 JMZ H X (15) (0) Y
INSPECTION COMMENTS: SIGN NOT REMOVED
 
(4) 07/28/2011 08/01/2011 MC2 C R E (30) (0) Y
INSPECTION COMMENTS: VIOLATIONS REMOVED

OBJECTION FOR APPLICATION #: B008874
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
NO SIGN TAG SIGN 56 INSTALLATIONA ND CONNECTION OF SIGN B30 211.0
RSLV 05/14/1986 01/26/2011 07/28/2011
 
002 ( 29) OUTLET BOXES ARE NOT COVERED
LIGHTS STORE FRONT
RSLV 05/14/1986 01/26/2011 07/28/2011
 
003 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
LIGHTS STORE FRONT 3 BR CIR CONNECTION OF SIGN
RSLV 05/14/1986 01/26/2011 07/28/2011



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.