| BUILDING OVERVIEW |
Are Feeders Being Installed? : |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
1 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| SUB FEEDERS (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
4 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
5 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| |
| (1) |
07/28/1986 |
08/12/1986 |
WMK |
N |
|
|
(10) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (2) |
02/06/1987 |
02/23/1987 |
SR1 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (3) |
02/28/1987 |
03/04/1987 |
SR1 |
N |
|
|
(10) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (4) |
03/23/1987 |
04/02/1987 |
WMK |
A |
|
B |
(50) |
|
(3) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (5) |
03/23/1987 |
07/27/1987 |
WMK |
A |
|
B |
(50) |
|
(3) |
|
| INSPECTION COMMENTS:
|
SCREW AT NEUTRAL OF DIS (B)SER SW NEUTR NOT PROPERLY BONDED (C)SERV ENT & EQUIP NOT BONDED (D)LOCKNUTS ARE MISSING SERV ENT NIPPLE
|
| |
| (6) |
09/04/1987 |
09/21/1987 |
JB1 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (7) |
10/16/1987 |
11/02/1987 |
JB1 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (8) |
12/08/1987 |
12/16/1987 |
WMK |
N |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (9) |
02/02/1988 |
02/04/1988 |
NEI |
H |
X |
B |
(45) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (10) |
03/18/1988 |
04/04/1988 |
WMK |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (11) |
05/25/1988 |
06/02/1988 |
FW1 |
N |
|
|
(30) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (12) |
06/30/1988 |
07/11/1988 |
MF1 |
H |
X |
B |
(60) |
|
(0) |
|
| INSPECTION COMMENTS:
|
CTO WAITED FOR ELEC DID NOT COME OWNER LET ME IN
|
| |
| (14) |
08/25/1988 |
08/30/1988 |
FW1 |
N |
|
|
(25) |
|
(0) |
|
| INSPECTION COMMENTS:
|
LEFT CARD
|
| |
| (15) |
10/06/1988 |
10/12/1988 |
FW1 |
C |
R |
E |
(50) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|