Electrical Application Details for App #: B004312
Premises: 1543 WEST 1 STREET BROOKLYN BIN: 3174676     Block: 6606   Lot: 26
   
Application Completed and Certified

Filed: 1543 W 1 ST Census Tract:   434 Health Area:  8521
6TH FL APT 9F Admin Area:   B - BROOKLYN Inspection Area:   N
BROOKLYN, NY 11204 Community Board:   311
DOB Cross Street(s):    65 STREET,    AVENUE P
Status:   C - JOB IS SIGNED OFF 01/30/1987
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/30/1986 Job Start Date:   06/24/1986
Last Change:   01/12/1987 Job End Date:   06/24/1986
Appointment Status:   
Last Inspection By:   MCEVOY, R.       On     01/05/1987      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010003 Licensee Name: ANTONIOS TAKOS
Firm: 001408 Firm Name: TAKOS AND K ELECTRIC INC
Firm Phone: 718-472-1300  Firm Address: 38-58 11TH STREET LONG ISLAND CITY NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $30.00
Other Work:   SUB-FEEDER FROM BSMNT TO APT 9F
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: R R MANAGMENT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: METER AT BASEMENT SUB FEEDER FROM BASEMENT TO 6FL APT 9F PANEL IN TH
Contractor's Comments:  METER BSMNT PANEL AT THE APT

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B004312
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/05/1987 01/12/1987 RM1 C E (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application