Electrical Application Details for App #: A369574
Premises: 34-40 113 STREET QUEENS BIN: 4043827     Block: 1756   Lot: 25
   

DOB NOW: Inspections


Filed: 34-74 113TH ST Census Tract:   381 Health Area:  1100
SCHOOL YARD Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11368 Community Board:   403
Special Place Name:   PS 143Q
DOB Cross Street(s):    34 AVENUE,    37 AVENUE
Status:   K - CLOSED/CANCELLED 12/14/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/17/2017 10:03 AM
Application Entered:   11/17/2017 Job Start Date:   11/17/2017
Last Change:   12/14/2017 Job End Date:   11/29/2019
Appointment Status:   
Last Inspection By:   WONG, K.       On     12/14/2017      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011357 Licensee Name: MONET MILAD
Firm: 001609 Firm Name: MILAD CONTRACTING CORP.
Firm Phone: 718-899-2400  Firm Address: 248-09 JAMAICA AVENUE BELLEROSE NY 11426 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
T - TEMPORARY LIGHT & POWER
Total Fee:  $415.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: GORDON TUNG
Owner Business Name: NYC SCA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  1  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/17/2017 Notice:  
Power Issued: 11/17/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TEMP SERVICE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A369574
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/14/2017 12/14/2017 KIW K (5) (0) Y
INSPECTION COMMENTS: SEE Q00003941