Electrical Application Details for App #: A365060
Premises: 659 SENECA AVENUE QUEENS BIN: 4082516     Block: 3454   Lot: 6
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 659 SENECA AV Census Tract:   547 Health Area:  2200
THROUGHOUT Admin Area:   A - QUEENS Inspection Area:   G
QUEENS, NY 11385 Community Board:   405
DOB Cross Street(s):   LINDEN STREET,    GATES AVENUE
Status:   C - JOB IS SIGNED OFF 02/06/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/26/2017 11:29 AM
Application Entered:   07/26/2017 Job Start Date:   07/26/2017
Last Change:   02/06/2018 Job End Date:   07/26/2018
Appointment Status:   
Last Inspection By:   WONG, K.       On     02/06/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009968 Licensee Name: SIGMOND FRIED
Firm: 000558 Firm Name: FRIED ELECTRIC CO.
Firm Phone: 718-389-2141  Firm Address: 67 WEST STREET, UNIT 321 BROOKLYN NY 11222 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $558.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ABE FRIEDMAN
Owner Business Name: NONE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  200 AMPS
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  6  #3
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  20-CIRCUIT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  6  30-CIRCUIT
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  PLP  20  20    20             
001  1L  12  25    10  12         
001  1R  12  25    10  12         
002  2L  12  25    10  12         
002  2R  12  25    10  12         
003  3L  12  25    10  12         
003  3R  12  25    10  12         
ROF  PLP                 
Buildings Total 96  172    68  96     30           
Total Units : 462 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 7 #4-Wire 0 #10-Wire 0
Existing Meters 7 + New Meters 7 - Removed Meters 7 = Total Meters 7

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 07/26/2017 Notice: 1 - FIRST NOTICE 01/19/2018
Power Issued: 07/26/2017 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A365060
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/19/2018 01/19/2018 DEX V (60) (6)
INSPECTION COMMENTS: RESOLVE DISPUTES FOR SIGN OFF
 
(2) 01/29/2018 01/29/2018 DEX H Y (45) (0)
INSPECTION COMMENTS: RESOLVE DISPUTE FOR SIGN OFF
 
(3) 02/06/2018 02/06/2018 KIW C R (4) (0)
INSPECTION COMMENTS: CONFIRMED WITH INSPECTOR DOYLEY, NO OBJECTION.

OBJECTION FOR APPLICATION #: A365060
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 17) DEFECTIVE SWITCHES ARE IN USE
(FLOOR: 001) 1ST FLOOR PANELS DEFECTIVE AFCI BREACKERS
RSLV 01/19/2018 01/19/2018 01/29/2018
 
002 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
(FLOOR: 001) 1ST FLOOR PANEL NEED A WASHER FITTING FOR RISER CABLE
RSLV 01/19/2018 01/19/2018 01/29/2018
 
003 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(ALL FLOORS)THROUGHOUT IN APARTMENTS INSUFFCENT OUTLETS IN BEDROOM AND HALLWAYS
RSLV 01/19/2018 01/19/2018 01/29/2018
 
004 (104) SERVICE CONDUCTORS IN HOLLOW SPACE OF FRAME BUILDING
(BASEMENT) UNFUSED CONDUCTORS IN HOLLOW FRAME OF BUILDING
RSLV 01/19/2018 01/19/2018 01/29/2018
 
005 (999) OTHER
(BASEMENT) SERVICE ROOM ONLY USED FOR SERVICE NO LAUNDRY. 110.26
RSLV 01/19/2018 01/19/2018 02/06/2018
 
006 (307) NO RECEPTACLE OUTLET WITHIN 25 FEET FOR HVAC EQUIPMENT
(ROOF) NEED GFCI OUTLET 25 FEET OF EQUIPMENT ON ROOF
RSLV 01/19/2018 01/19/2018 01/29/2018