Electrical Application Details for App #: A363778
Premises: 70-33 260 STREET QUEENS BIN: 4456460     Block: 8443   Lot: 1
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 70-33 260TH ST Census Tract:   1551.02 Health Area:  2170
260TH ST Admin Area:   A - QUEENS Inspection Area:   F
QUEENS, NY 11004 Community Board:   413
DOB Cross Street(s):    252 STREET,    LANGSTON AVENUE
Status:   C - JOB IS SIGNED OFF 04/24/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/21/2017 11:03 AM
Application Entered:   06/21/2017 Job Start Date:   06/21/2017
Last Change:   04/24/2018 Job End Date:   09/01/2017
Appointment Status:   
Last Inspection By:   MICHAEL BENISCHEK       On     08/23/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012760 Licensee Name: RUSSELL S CASTALDO
Firm: 004604 Firm Name: ABSOLUTE ELECL SVCE INC
Firm Phone: 718-229-9300  Firm Address: 224-08 LINDEN BOULEVARD CAMBRIA HEIGHTS NY 11411 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $44.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: GLEN OAKS VILLAGE OWNERS,
Authorized Representative:  VICTOR SOLIVEN
Relationship To Owner:   PURCHASING COORDINATOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
GND    10         
Buildings Total 10              
Total Units : 26 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/01/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A363778
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/29/2017 06/29/2017 NRS V (48) (6)
INSPECTION COMMENTS: NEW SUNROOM WIRING.
 
(2) 08/01/2017 08/01/2017 ECH V R (60) (1)
INSPECTION COMMENTS: SEE OBJECTIONS
 
(3) 08/23/2017 08/23/2017 MBE C R (45) (0)
INSPECTION COMMENTS: CORRECTIONS MADE TO OBJECTIONS ON THE NEW A/C OUTSIDE UNIT BEHIND THE GLASS BREAK ROOM

OBJECTION FOR APPLICATION #: A363778
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (128) NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH
(GROUND FLOOR) NSC EGC TERMINATED ON NEUTRAL BAR
RSLV 06/29/2017 06/29/2017 08/01/2017
 
002 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(GROUND FLOOR) CRAWL SPACE SPLICE BOXES NOT BONDED
RSLV 06/29/2017 06/29/2017 08/01/2017
 
003 (243) CONDUCTORS OF THE SAME CIRCUIT NOT GROUPED
(GROUND FLOOR) (2) 12/3 USED FOR (3) 2-WIRE CIRCUIT
RSLV 06/29/2017 06/29/2017 08/01/2017
 
004 (999) OTHER
(GROUND FLOOR) A/C OVERFUSED 440.22(C)
RSLV 06/29/2017 06/29/2017 08/01/2017
 
005 (110) SUFFICIENT WORK SPACE IS NOT PROVIDED/MAINTAINED
(OPEN SPACE) A/C DISCONNECT
RSLV 06/29/2017 06/29/2017 08/01/2017
 
006 (999) OTHER
(OPEN SPACE) LFMC NOT SECURED AT A/C DISCONNECT 350.30
RSLV 06/29/2017 06/29/2017 08/01/2017
 
007 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
(GROUND FLOOR)208 VOLT BETWEEN CONDENSER AND BLOWER FOR MITSUBISHI SPLIT SYSTEMMUST BE WIRED IN APPROVED WIRING METHOD
RSLV 08/01/2017 08/01/2017 08/23/2017