| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| SUB FEEDERS (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
2 |
4/3 |
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
2 |
125A 12CKT |
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(128) |
NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH (FLOOR: 001) 1K: NEUTRALS TERMINATED ON GROUND BAR IN PANEL |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 002 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE (FLOOR: 001) GFCI ON THE LEFT OF RANGE |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 003 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE (FLOOR: 001) GFCI BOX ON THE LEFT OF RANGE LOOSE 406.5 |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 004 |
(229) |
SPLICE BOXES NOT ACCESSIBLE (FLOOR: 001) FEEDER EXTENSION SPLICE BOX IN CEILING |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 005 |
( 29) |
OUTLET BOXES ARE NOT COVERED (FLOOR: 001) 1K: SPLICE BOX IN CABINET ON THE RIGHT OF STOVE |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 006 |
( 58) |
FIXTURE NOT PROPERLY LOCATED IN CLOTHES CLOSET (FLOOR: 001) - |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 007 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED (FLOOR: 001) FGFCI BREAKER USED ON LIVINGROOM NEW BOXES |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |
| |
| 008 |
(999) |
OTHER (FLOOR: 001) MICRO/HOOD BOX SET TOO DEEP 314.20 |
RSLV |
02/24/2017 |
02/24/2017 |
03/15/2017 |