BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A354782
Premises: 41-09 49 STREET QUEENS BIN: 4001158     Block: 134   Lot: 25
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 41-11 49TH ST Census Tract:   253.01 Health Area:  0910
RESTAURANT Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11104 Community Board:   402
DOB Cross Street(s):   SKILLMAN AVENUE,    43 AVENUE
Status:   C - JOB IS SIGNED OFF 02/21/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/14/2016 8:09 AM
Application Entered:   10/14/2016 Job Start Date:   10/14/2016
Last Change:   02/21/2018 Job End Date:   01/14/2017
Appointment Status:   
Last Inspection By:   ERIC HIRSCH       On     02/16/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012505 Licensee Name: YLL LOXHAJ
Firm: 004320 Firm Name: AMSTERDAM ELECTRIC CORP
Firm Phone: 718-392-4838  Firm Address: 36-28 9TH STREET LONG ISLAND CITY NY 11106 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $212.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JONATHAN CORDEIRO
Owner Business Name: THE ALCOVE RESTAURANT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  3   3 OT
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  42 CIRCUIT
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/14/2016 Notice: 1 - FIRST NOTICE 02/12/2018
Power Issued: 10/14/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A354782
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/10/2018 01/11/2018 MBE V (37) (2)
INSPECTION COMMENTS: OBJECTION ISSUED.
 
(2) 02/05/2018 02/12/2018 NRS V R (27) (1)
INSPECTION COMMENTS: OBJECTIONS REMOVED.
 
(3) 02/16/2018 02/16/2018 ECH C R (25) (0)
INSPECTION COMMENTS: PASS

OBJECTION FOR APPLICATION #: A354782
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (181) DISCONNECTING MEANS IS IMPROPER/NOT PROVIDED
(CELLAR)NO MEANS OF DISCONNECT FOR 200 AMP RESTAURANT (DISCONNECT IS THREESTORES AWAY OVER 50'. ARTICLE # 620.51
RSLV 01/10/2018 01/10/2018 02/05/2018
 
002 (275) GROUNDING ELECTRODE CONDUCTOR IS DEFECTIVE
(CELLAR)NO WATER MAIN GROUND PROVIDED, ONLY GROUND ROD. ARTICLE # 250.64
RSLV 01/10/2018 01/10/2018 02/05/2018
 
003 (279) WATER METER JUMPER IS MISSING/IMPROPER
(BASEMENT) FOR RESTAURANT SUBMETER AT 41-11
RSLV 02/05/2018 02/05/2018 02/16/2018



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.