Electrical Application Details for App #: A352768
Premises: 42-11 COLLEGE POINT BOULEVARD QUEENS BIN: 4538171     Block: 5101   Lot: 7
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 42-11 COLLEGE POINT BLVD Census Tract:   849 Health Area:  1200
APT# 2R Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11355 Community Board:   407
DOB Cross Street(s):   SANFORD AVENUE,    MAPLE AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/24/2016 2:12 PM
Application Entered:   08/24/2016 Job Start Date:   08/26/2016
Last Change:   08/22/2025 Job End Date:   11/10/2016
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   SCHUSZTER, NORBET       On     09/16/2016      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  

License #: 011030 Licensee Name: DEYI LING
Firm: 004259 Firm Name: HV ELECTRIC CORP
Firm Phone: 718-321-8962  Firm Address: 36-17 BUD PLACE FLUSHING NY 11354 

Removal of ECB Violation(s): 35169837N              
Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $69.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: HUA HU
Authorized Representative:  HUA HU
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  #6/3
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  125A 14CRT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002  2R  10         
Buildings Total 10              
Total Units : 31 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 09/16/2016
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  FINISH THE JOB STARTING BY UNKNOWN CONTRACTOR.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A352768
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/16/2016 09/16/2016 NRS V (58) (13)
INSPECTION COMMENTS: JOB INCOMPLETE.

OBJECTION FOR APPLICATION #: A352768
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (132) EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED
(FLOOR: 002) #14AWG GROUNDING BONDING IN USE
OPEN 09/16/2016 09/16/2016
 
002 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 002) NEUTRAL BRIDGE BETW. NEUTRAL BARS UNDERSIZED
OPEN 09/16/2016 09/16/2016
 
003 ( 19) DEFECTIVE WIRING IS IN USE
(FLOOR: 002) DEVICES PIGTAILED WITH #14AWG WIRE
OPEN 09/16/2016 09/16/2016
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
(FLOOR: 002) -
OPEN 09/16/2016 09/16/2016
 
005 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(FLOOR: 002) LFNC USED AT AC
OPEN 09/16/2016 09/16/2016
 
006 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(FLOOR: 002) ROMEX USED BETWEEN A/H & A/C UNIT
OPEN 09/16/2016 09/16/2016
 
007 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(FLOOR: 002) OUTSIDE AC GFCI
OPEN 09/16/2016 09/16/2016
 
008 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
(FLOOR: 002) 2R
OPEN 09/16/2016 09/16/2016
 
009 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
(FLOOR: 002) OUTSIDE AT AC
OPEN 09/16/2016 09/16/2016
 
010 (999) OTHER
(FLOOR: 002) #14AWG CONDUCTORS USED FOR AC POWER
OPEN 09/16/2016 09/16/2016
 
011 (999) OTHER
(FLOOR: 002) NO BREAKER TIE ON MULTI-WIRE CIRCUITS 210.4
OPEN 09/16/2016 09/16/2016
 
012 (999) OTHER
(FLOOR: 002) A/C OVER FUSED 440.22(C)
OPEN 09/16/2016 09/16/2016
 
013 (999) OTHER
(FLOOR: 002) DEVICES LOOSE IN BOXES
OPEN 09/16/2016 09/16/2016