Electrical Application Details for App #: A345319
Premises: 36-20 168 STREET QUEENS BIN: 4312301     Block: 5294   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 36-20 168 ST Census Tract:   1175 Health Area:  1310
ENTIRE BUILDING Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11358 Community Board:   407
DOB Cross Street(s):   CROCHERON AVENUE,    DEPOT ROAD
Status:   C - JOB IS SIGNED OFF 05/18/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/24/2016 12:19 AM
Application Entered:   01/24/2016 Job Start Date:   01/26/2016
Last Change:   05/18/2016 Job End Date:   12/26/2016
Appointment Status:   
Last Inspection By:   ERIC HIRSCH       On     05/06/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012398 Licensee Name: WEN BIN CEN
Firm: 004190 Firm Name: R & T ELECTRICAL CORP
Firm Phone: 718-526-6888  Firm Address: 36-03B COLLEGE POINT BLVD BSMNT FLUSHING NY 11354 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $1,210.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   CONDOMINIUM
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: THOMAS FAN
Owner Business Name: FENCE ASSOCIATES,LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  78  8-16 CIRCUIT
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACE ALL FEDERAL PACIFIC PANEL FOR EACH APARTMENT.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A345319
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/06/2016 05/06/2016 ECH C (135) (0) Y
INSPECTION COMMENTS: NONE