BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A337785
Premises: 23-36 31 DRIVE QUEENS BIN: 4607260     Block: 567   Lot: 40
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 23-36 31 DR Census Tract:   75 Health Area:  0300
WHOLE BUILDING Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11106 Community Board:   401
Related Job Number:    420651011
DOB Cross Street(s):    23 STREET,    CRESCENT STREET
Status:   C - JOB IS SIGNED OFF 12/17/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/20/2015 1:35 PM
Application Entered:   05/20/2015 Job Start Date:   05/20/2015
Last Change:   12/17/2015 Job End Date:   05/20/2016
Appointment Status:   
Last Inspection By:   DOYLEY, DEXTER       On     12/02/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011710 Licensee Name: GEORGE POULAKIS
Firm: 003293 Firm Name: G. POULAKIS ELEC'L CONTR'
Firm Phone: 347-642-5754  Firm Address: 18-40 42ND STREET INC. ASTORIA NY 11105 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $1,492.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SAL LUCCHESE
Owner Business Name: 31 DRIVE LLC
Authorized Representative:  SAL LUCCHESE
Relationship To Owner:   OFFICER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  2  400 AND 600 AMP
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  23  #2 THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  3  500 MCM AND 350 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  23  20 CKT PANEL
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    15    15             
LOB    38  14    38             
001    24  45    30  24             
002    32  60    40  32             
003    40  75    50  40             
004    40  75    50  40             
005    40  75    50  40             
ROF      30  30         
Buildings Total 237  356    229  237     30           
Total Units : 1089 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 22 #4-Wire 0 #10-Wire 1
Existing Meters 1 + New Meters 23 - Removed Meters 1 = Total Meters 23

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 05/20/2015 Notice:  
Power Issued: 05/20/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WHOLE BUILDING AND ONLY ELEVATOR DISCONNECTS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A337785
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/02/2015 12/03/2015 DEX C E (155) (0) Y
INSPECTION COMMENTS: CERTIFICATE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back