BIS Menu  |  Electrical Applications  |  Comments  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A331631
Premises: 5-12 51 AVENUE QUEENS BIN: 4000184     Block: 34   Lot: 29
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 5-12 51 AV Census Tract:   7 Health Area:  0720
ROOF, BSMT, 1,2,3,4 FLRS Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
DOB Cross Street(s):    5 STREET,    VERNON BOULEVARD
Status:   C - JOB IS SIGNED OFF 01/22/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/23/2014 2:24 PM
Application Entered:   10/23/2014 Job Start Date:   10/23/2014
Last Change:   01/22/2016 Job End Date:   03/30/2015
Appointment Status:   
Last Inspection By:   SAMARAS TASOS       On     11/02/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012072 Licensee Name: CLINTON COURTNEY
Firm: 003770 Firm Name: TRINCITY ELECTRIC, INC
Firm Phone: 718-712-4300  Firm Address: 224-17 MERRICK BLVD SPRINGFIELD GARDENS NY 11413 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $95.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CHARLES KIM
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  BSMT  10    10             
001  1FL  20    20             
002  2FL  20    20             
003  3FL  18    18             
004  4FL  20    20             
ROF  ROOF                 
Buildings Total 90  26    24  90                
Total Units : 230 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/03/2015
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A331631
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/01/2015 05/06/2015 RYP Z (0) (0) Y
INSPECTION COMMENTS: NOT INSPECTED
 
(2) 07/27/2015 08/03/2015 COB A (50) (7) Y
INSPECTION COMMENTS: VIOLATIONS
 
(3) 08/24/2015 09/01/2015 EVG N (29) (0) Y
INSPECTION COMMENTS: NO ACCESS
 
(4) 09/16/2015 09/28/2015 DEX J Y (40) (0) Y
INSPECTION COMMENTS: JOB IN PROGRESS. NO COMMENTS
 
(5) 10/13/2015 10/19/2015 EVG P (25) (0) Y
INSPECTION COMMENTS: PARTIAL ACCESS
 
(6) 11/02/2015 11/09/2015 TS1 C R (15) (0) Y
INSPECTION COMMENTS: CERTIIFCATE

OBJECTION FOR APPLICATION #: A331631
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
ROOF BALCONY 1ST FL BASEMENT OUTSIDE GFCI RECEPTACLES TR, WR RECEPTACLES NOT PROVIDED 406.11/406.8
RSLV 07/27/2015 07/27/2015 09/16/2015
 
002 (999) OTHER
ROOF BALCONY, 1ST FL, BASEMENT OUTSIDE GFCI IN USE COVER NOT PROVIDED 406.8
RSLV 07/27/2015 07/27/2015 09/16/2015
 
003 (999) OTHER
ALL APARTMENTS KITCHEN AND BATHROOM GFCI RECEPTACLE TR RECEPTACLES NOT 406.8
RSLV 07/27/2015 09/16/2015 11/02/2015
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
2ND FL LEFT APT PANEL COMBO AFCI NOT PROVIDED
RSLV 07/27/2015 09/16/2015 11/02/2015
 
005 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
2ND FL SUB PANELS
RSLV 07/27/2015 09/16/2015 11/02/2015
 
006 ( 53) GFCI HAS NOT BEEN PROVIDED
3RD FL JACUZZI RECEPTACLE
RSLV 07/27/2015 09/16/2015 11/02/2015
 
007 ( 53) GFCI HAS NOT BEEN PROVIDED
1ST FL KITCHEN PENINSULA RECEPTACLE
RSLV 07/27/2015 07/27/2015 09/16/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.