BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A327702
Premises: 31-53 14 STREET QUEENS BIN: 4005810     Block: 531   Lot: 35
   
Application Completed and Certified

Filed: 31-53 14 ST Census Tract:   77 Health Area:  0300
ALL Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11106 Community Board:   401
DOB Cross Street(s):    31 DRIVE,    BROADWAY
Status:   C - JOB IS SIGNED OFF 09/18/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/13/2014 10:46 AM
Application Entered:   06/13/2014 Job Start Date:   06/13/2014
Last Change:   09/18/2014 Job End Date:   06/13/2015
Appointment Status:   
Last Inspection By:   SAMARAS TASOS       On     09/15/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012012 Licensee Name: SAMY A MOUNAS
Firm: 003639 Firm Name: GOLD STAR ELECT'L, INC
Firm Phone: 718-961-7827  Firm Address: 59-24 57TH STREET MASPETH NY 11378 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $68.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: UMBERTO MACCARRONE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  12  20  12             
002  13  32  13             
Buildings Total 25  52  13  25                
Total Units : 122 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/19/2014
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A327702
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/30/2014 08/05/2014 TS1 V (30) (5) Y
INSPECTION COMMENTS: VIOLATIONS
 
(2) 08/12/2014 08/19/2014 TSO A R (90) (2) Y
INSPECTION COMMENTS: VIOLATIONS
 
(3) 09/15/2014 09/18/2014 TS1 C R (30) (0) Y
INSPECTION COMMENTS: CERTFICIATE

OBJECTION FOR APPLICATION #: A327702
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
PANEL NO DIRECTORY PROVIDED FOR 1ST FLOOR PANEL
RSLV 07/30/2014 07/30/2014 08/12/2014
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
PANEL NO AFCI PROTECTION PROVIDED. MUST BE COMBO TYPE BREAKERS
RSLV 07/30/2014 07/30/2014 08/12/2014
 
003 (999) OTHER
SERVICE 3-WIRES UNDER SPLIT BOLT NOT APPROVED IN THE TROUGH
RSLV 07/30/2014 07/30/2014 08/12/2014
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
PANEL 1ST FLOOR APARTMENT MUST HAVE 2 APPLIANCE BRANCH CIRCUITS. NO GFCI PROVIDED FOR COUNTERTOP
RSLV 07/30/2014 07/30/2014 08/12/2014
 
005 (999) OTHER
PANELS TWO POLE BRAKERS NOT PROVIDED FOR 3-WIRE BY 210.12B
RSLV 07/30/2014 07/30/2014 08/12/2014
 
006 ( 53) GFCI HAS NOT BEEN PROVIDED
PANEL 1ST FLOOR APARTMENT MUST HAVE 2 APPLIANCE BRANCH CIRCUITS. NO GFCI PROVIDED FOR COUNTERTOP
RSLV 08/12/2014 08/12/2014 09/15/2014
 
007 (999) OTHER
BATHROOM ON W/ COUNTER CIR 210.52
RSLV 08/12/2014 08/12/2014 09/15/2014



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back