Electrical Application Details for App #: A325330
Premises: 44-19 PURVES STREET QUEENS BIN: 4461880     Block: 267   Lot: 14
   
Application Completed and Certified

Filed: 44-19 PURVES ST Census Tract:   19 Health Area:  0720
CELLER / FIRST FL Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Related Job Number:    420356983
DOB Cross Street(s):   JACKSON AVENUE,    DEAD END
Status:   C - JOB IS SIGNED OFF 01/22/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/19/2014 1:17 PM
Application Entered:   03/19/2014 Job Start Date:   03/19/2014
Last Change:   01/22/2015 Job End Date:   03/19/2015
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     10/15/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 012157 Licensee Name: ALPESHKUMAR PATEL
Firm: 003859 Firm Name: VOLTAMP ELECT'L CONTR'S
Firm Phone: 718-874-7500  Firm Address: 88-55 76TH AVENUE INC GLENDALE NY 11385 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
Total Fee:  $355.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   SCULPTURE CENTER
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: AHMEAD MIKE
Owner Business Name: NYC DDC / ADAM DEVELOPERS
Authorized Representative:  AHMEAD MIKE
Relationship To Owner:   GC


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  3  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    15               
001    20  12    12               
Buildings Total 35  18  18                  
Total Units : 72 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/17/2014
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  COMPLETION OF ELECTRICAL WORK STARTED BY OTHERS - PERMIT # A319476

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A325330
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/15/2014 09/17/2014 TSO A (85) (7) Y
INSPECTION COMMENTS: VIOLATIONS
 
(2) 10/15/2014 10/21/2014 KAS C R G (105) (0) Y
INSPECTION COMMENTS: CERTIFICATE

OBJECTION FOR APPLICATION #: A325330
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
T/OUT MULTIWIRE CIRCUITS NEEDS GROUPS AND TIES 210.4B&D
RSLV 09/15/2014 09/15/2014 10/15/2014
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
T/OUT BOXES NOT BONDED MC CABLE INCLUDE WIRE MOLD
RSLV 09/15/2014 09/15/2014 10/15/2014
 
003 (999) OTHER
YARD/ROOF NO WR RECEPTACLE WRONG COVER 406.8B
RSLV 09/15/2014 09/15/2014 10/15/2014
 
004 (999) OTHER
T/OUT COVERS TO BALLAST MISSING 314.25
RSLV 09/15/2014 09/15/2014 10/15/2014
 
005 (999) OTHER
ALL RAEWAY NOT CONTINUOUS BALLAST FLUORESCENT 300.10
RSLV 09/15/2014 09/15/2014 10/15/2014
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
BATHROOM PULL BOXES NOT GROUNDED
RSLV 09/15/2014 09/15/2014 10/15/2014
 
007 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
ROOF A/C DISCONNECT NOT BONDED
RSLV 09/15/2014 09/15/2014 10/15/2014