BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A304832
Premises: 232 BEACH 100 STREET QUEENS BIN: 4616237     Block: 16155   Lot: 15
   
Application Completed and Certified

Filed: 232 BEACH 100 ST Census Tract:   942.01 Health Area:  3700
1-3 Admin Area:   A - QUEENS Inspection Area:   M
QUEENS, NY 11694 Community Board:   414
Related Job Number:    402431980
DOB Cross Street(s):   STEEPLECHASE COURT,    DEAD END
Status:   C - JOB IS SIGNED OFF 10/13/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/05/2012 1:27 PM
Application Entered:   09/05/2012 Job Start Date:   09/09/2012
Last Change:   10/13/2015 Job End Date:   09/01/2013
Appointment Status:   
Last Inspection By:   POMERICO, RAYMOND E       On     10/06/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011193 Licensee Name: ALBERT N FAELLA
Firm: 000907 Firm Name: M F ELEC'L SVC CO., INC
Firm Phone: 718-547-2400  Firm Address: 3323 MERRITT AVENUE BRONX NY 10475 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $214.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: WETHERALL CONTRACTING
Authorized Representative:  BRIAN WETHERALL
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  60 AMP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  1/0
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  4  12/24
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  12  28  12             
002  12  28  12             
003  19  39  12  19             
Buildings Total 43  95  10  28  43                
Total Units : 219 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 4 - Removed Meters 0 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/05/2012 Notice:  
Power Issued: 09/05/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CODE WIRING OF 3 UNIT BUILDING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A304832
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/26/2015 06/30/2015 RYP J G (20) (0) Y
INSPECTION COMMENTS: SEE APPLICATION A324760
 
(2) 10/06/2015 10/13/2015 RYP C E (15) (0) Y
INSPECTION COMMENTS: CERTIFICATE.SEE APPLICATION A324760