Electrical Application Details for App #: A304826
Premises: 41-75 SUMMIT COURT QUEENS BIN: 4529633     Block: 5101   Lot: 29
   
Application Completed and Certified

Filed: 41-75 SUMMIT COURT Census Tract:   849 Health Area:  1200
STREET Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11355 Community Board:   407
DOB Cross Street(s):   SANFORD AVENUE,    DEAD END
Status:   C - JOB IS SIGNED OFF 01/29/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/05/2012 11:32 AM
Application Entered:   09/05/2012 Job Start Date:   09/06/2012
Last Change:   01/29/2013 Job End Date:   09/14/2012
Appointment Status:   
Last Inspection By:   THEODORE JUNSCH       On     09/18/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010436 Licensee Name: ANTHONY BRACCO
Firm: 000016 Firm Name: A & B ELECTRIC, INC
Firm Phone: 718-460-8666  Firm Address: 45-58 162ND STREET FLUSHING NY 11358 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $55.00
Other Work:   REPAIR 1 METER SOCKET
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CHRISTENE CHEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 4 #4-Wire 0 #10-Wire 0
Existing Meters 4 + New Meters 1 - Removed Meters 1 = Total Meters 4

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/05/2012 Notice:  
Power Issued: 09/05/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPAIRING ONE SOCKET IN THE 3-GANG METER PAN.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A304826
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/18/2012 09/25/2012 TJ1 C E (45) (0) Y
INSPECTION COMMENTS: CERTIFICATE