Electrical Application Details for App #: A304070
Premises: 98-16 41 AVENUE QUEENS BIN: 4040419     Block: 1614   Lot: 21
   
Application Completed and Certified

Filed: 98-16 41 AV Census Tract:   409 Health Area:  1100
BASEMENT AND GROUND FLOOR Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11368 Community Board:   404
DOB Cross Street(s):    98 STREET,    99 STREET
Status:   C - JOB IS SIGNED OFF 12/12/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/06/2012 1:48 PM
Application Entered:   08/06/2012 Job Start Date:   08/06/2012
Last Change:   12/12/2012 Job End Date:   08/31/2012
Appointment Status:   
Last Inspection By:   SAMARAS TASOS       On     12/06/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011877 Licensee Name: ANTHONY CERRITO
Firm: 003392 Firm Name: A & R ELEC'L MAINT. INC.
Firm Phone: 718-639-0800  Firm Address: 85-47 GRAND AVE ELMHURST NY 11373 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $147.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   E - Four Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: VICTOR DUTAN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  4  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  4  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 5 #4-Wire 0 #10-Wire 0
Existing Meters 5 + New Meters 5 - Removed Meters 5 = Total Meters 5

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/06/2012 Notice:  
Power Issued: 08/06/2012 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL METERS OUTSIDE.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A304070
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/14/2012 11/19/2012 EBT Z (0) (0) Y
INSPECTION COMMENTS: NOT INSPECTED
 
(2) 12/06/2012 12/11/2012 TS1 C E (30) (0) Y
INSPECTION COMMENTS: CERTIFICATE