BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A302307
Premises: 120-55 QUEENS BOULEVARD QUEENS BIN: 4052812     Block: 2274   Lot: 2
   
Application Completed and Certified

Filed: 120-55 QUEENS BLVD Census Tract:   216 Health Area:  2710
BASEMENT AND ROOF Admin Area:   A - QUEENS Inspection Area:   H
QUEENS, NY 11415 Community Board:   409
Special Place Name:   QUEENS BOROUGH HALL
DOB Cross Street(s):   CONNECTOR ROAD TO UNION TPKE EB,    82 AVENUE
Status:   C - JOB IS SIGNED OFF 06/16/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/22/2012 2:04 PM
Application Entered:   05/22/2012 Job Start Date:   05/23/2012
Last Change:   06/16/2014 Job End Date:   07/30/2012
Appointment Status:   
Last Inspection By:   SAMARAS TASOS       On     06/11/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010508 Licensee Name: PAT A VERNO
Firm: 004022 Firm Name: BANA ELEC CORP. OF NEW YO
Firm Phone: 718-701-5988  Firm Address: 42-32 235TH STREET DOUGLASTON NY 11363 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $40.00
Other Work:   MOTOR CONTROLERS
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSEPH WAGNER
Owner Business Name: QUEENS BOROUGH HALL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                     
Buildings Total                       
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REPLACEMENT OF 7- MOTOR STARTERS TO VFD/MOTOR STARTER(BOILER ROOM) AND 1- ELECTRIC HOT WATER TANK

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A302307
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/11/2014 06/16/2014 TS1 C (30) (0) Y
INSPECTION COMMENTS: CERTIFICATE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Applications  |  Electrical Inspection Work Order  |  Back