NYC Department of Buildings
Electrical Application Details for App #: A301982
Premises: 32-01 30 AVENUE QUEENS BIN: 4008604     Block: 618   Lot: 1
   
Application Completed and Certified

Filed: 32-07 30 AV Census Tract:   71 Health Area:  0300
BASEMENT&1ST Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11102 Community Board:   401
DOB Cross Street(s):    32 STREET,    33 STREET
Status:   C - JOB IS SIGNED OFF 06/25/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/09/2012 7:37 AM
Application Entered:   05/09/2012 Job Start Date:   05/09/2012
Last Change:   06/25/2012 Job End Date:   05/14/2012
Appointment Status:   
Last Inspection By:   THEODORE JUNSCH       On     05/31/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011282 Licensee Name: STEVEN CRAWLEY
Firm: 002684 Firm Name: RENAISSANCE ELECTRIC CORP
Firm Phone: 718-515-2853  Firm Address: 2359 WESTCHESTER AVENUE BRONX NY 10461 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $44.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   CAFE
Special Cert Approval:   E - EMERGENCY LIGHTING LOCAL LAW 16/84
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MICOS CONSTANTINOU
Owner Business Name: ATHENS CAFE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                     
001    10        10             
Buildings Total 13        13                
Total Units : 26 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  PLAN#402002890

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A301982
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/31/2012 06/07/2012 TJ1 C (45) (0) Y
INSPECTION COMMENTS: CERTIFICATE