Electrical Application Details for App #: A300470
Premises: 43-06 58 STREET QUEENS BIN: 4031184     Block: 1330   Lot: 22
   
Application Completed and Certified

Filed: 43-06 58 ST Census Tract:   251 Health Area:  0920
REDIRECT VIOLATIONS A155595 Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11377 Community Board:   402
DOB Cross Street(s):    43 AVENUE,    44 AVENUE
Status:   C - JOB IS SIGNED OFF 05/03/2012
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   04/13/2012 Job Start Date:   04/13/2012
Last Change:   05/03/2012 Job End Date:   06/01/2012
Appointment Status:   
Last Inspection By:   ERROL FLYNN FRANKLIN       On     04/30/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011641 Licensee Name: RUI JUN HUANG
Firm: 003603 Firm Name: JUN SAFETY ELECTRICAL INC
Firm Phone: 718-331-2633  Firm Address: 2206 AVENUE U BROOKLYN NY 11229 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $56.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: RGS REALTY INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                 
Buildings Total                 
Total Units : 16 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  03/02/2012
Power Issued: Response: F - FILED TO REMOVE OBJECTION 04/13/2012

Follow-Up: X - FILED APPL,NOW CLOSED 04/13/2012
Contractor's Comments:  REDIRECT VIOLATIONS TO OWNER FROM APPL# A155595

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A300470
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/01/2012 03/02/2012 KIW W (10) (1)
INSPECTION COMMENTS: REDIRECT VIOLATIONS FROM APPL# A155595 LOUIS J FRANCHINO
 
(2) 04/30/2012 05/03/2012 EFF C R (30) (0) Y
INSPECTION COMMENTS: COMPLETED

OBJECTION FOR APPLICATION #: A300470
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
BASEMENT PANEL RIGHT SIDE LIGHTING ON 20AMP BREAKERREDIRECT VIOLATIONS APPL# A155595 ELECTRICIAN LOUIS J FRANCHINO
RSLV 03/01/2012 03/01/2012 04/30/2012