Electrical Application Details for App #: A290159
Premises: 43-30 DUTCH KILLS STREET QUEENS BIN: 4859865     Block: 267   Lot: 25
   
Application Completed and Certified

Filed: 43-30 DUTCH KILLS ST Census Tract:   1900 Health Area:  0720
GROUND Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Special Place Name:   SAFETY SYSTEMS
Related Job Number:    402879961
DOB Cross Street(s):   JACKSON AVENUE,    ED KOCH BR UPPER RDWY EN THOMSON
Status:   C - JOB IS SIGNED OFF 10/15/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/25/2010 12:08 PM
Application Entered:   10/25/2010 Job Start Date:   11/01/2010
Last Change:   10/15/2012 Job End Date:   11/01/2011
Appointment Status:   
Last Inspection By:   BOTSCH, E       On     10/04/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012063 Licensee Name: GREGORY BARTOCCI
Firm: 003754 Firm Name: CORE ELEC & COMMUNICATION
Firm Phone: 718-605-3597  Firm Address: 40 MARBLE LOOP SUITE G STATEN ISLAND NY 10309 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
T - TEMPORARY LIGHT & POWER
Total Fee:  $113.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   MIXED USE/PARKING LO
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: SCHOOL CONSTRUCTION AUTHO
Authorized Representative:  GREGORY BARTOCCI
Relationship To Owner:   LICENSEE


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 10/25/2010 Notice:  
Power Issued: 10/25/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  PROVIDE NEW POWER AND LIGHTING FOR PRE-FABRICATED TRAILER AND SIGHT LIGHTING AND PARKING LOT LIGHTING.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A290159
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/19/2012 07/25/2012 TJ1 N (30) (0) Y
INSPECTION COMMENTS: CONTRACTOR NO SHOW
 
(2) 08/23/2012 08/27/2012 TJ1 J E (60) (0) Y
INSPECTION COMMENTS: SERVICE EQUIPMENT NOT ENCLOSED
 
(3) 10/04/2012 10/15/2012 EBT C E (45) (0) Y
INSPECTION COMMENTS: CERTIFICATE