BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A286229
Premises: 2-26 50 AVENUE QUEENS BIN: 4616494     Block: 16   Lot: 38
   

Filed: 2-26 50TH AV Census Tract:   1 Health Area:  0720
STREET Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Special Place Name:   TEMP. HOIST
DOB Cross Street(s):    2 STREET,    5 STREET
Status:   K - CLOSED/CANCELLED 04/08/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/19/2010 7:55 AM
Application Entered:   05/19/2010 Job Start Date:   05/19/2010
Last Change:   04/08/2011 Job End Date:   05/05/2011
Appointment Status:   
Last Inspection By:   BOTSCH, E       On     03/24/2011      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011990 Licensee Name: DECLAN W DELAHUNTY
Firm: 003662 Firm Name: SHUIR ELEC'L CONTR'S CORP
Firm Phone: 718-414-4840  Firm Address: 4360 BULLARD AVENUE BRONX NY 10466 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $70.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   TEMP HOIST CAR
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: EDMUND KIRSCH
Owner Business Name: PERIMETER BRIDGE & SCAFFO
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  ONE 200AMP DISCONNECT
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  CONNECT POWER FOR PERSONNEL/MATERIAL HOIST CAR TO SECONDARYSIDE OF 208/480V TRANSFORMER PROVIDED BY BUILDING. INSTALLEDONE 200AMP, 3PH, 480V DISCONNECT FOR HOIST CAR.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A286229
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/24/2011 04/08/2011 EBT K (5) (0) Y
INSPECTION COMMENTS: REMOVED




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order